PearsonPortable Heater & Chiller System

Pearson Model P-10-25W 3,500,000 btu/hr, 10,000 Gallon Direct-Fired Water Heating System
Recovery capability: 3,540 gph at 100 degree rise. Total available gallons in an 8 hour day at 100 degree rise is 38,320.  Dimensions:  length 32’-2”, width 8’-7”,  height 9’-3”.  Unit is designed to be transported empty only.  Tank Insulation is 3 1/2” thick mineral wool insulation covered with plastic vapor barrier for cold water storage.

Pearson Model PH-1400  55 Ton Air Cooled Water Chiller
Recovery capability based on 80 degree water being cooled to 40 degrees with average ambient temperature of 95 degrees, is 1,600 gallons per hour. 
Plant Supply Pump: Horizontal centrifugal pump 3” flanged suction port, 3” flanged discharge port, direct coupled, rated at 300 gpm, 230/460 volt, 3 phase, 3500 rpm

Portability for 10,000 Gallon Hot Water Systems Includes: Gooseneck extension of tank skid with standard fifth wheel pin, single axle assembly with dual wheels and tires, airbrakes, mud flaps, fenders, running lights, one set crank down landing gear. Unit is designed to be transported empty, only.

Production range Hot & Cold Water for 1,000 Yards of Concrete.