CALTRANS ALLOWS THE RE-USE OF RETURN PLASTIC CONCRETE INTO FRESH CONCRETE FOR STATE PROJECTS.

May 17, 2016

Through the Materials & QA Subtask Group of the Concrete Task Group of the Rock Products Committee (RPC), Caltrans and Industry partnered to create a specification that would allow the use of recycled concrete for certain applications.  Section 90-7 includes specifications for incorporating returned plastic concrete (RPC) into concrete.  RPC must be used only where the specifications allow its use. Do not use RPC in pavement or structural concrete.

Background:
RPC “provides leadership and commitment to develop and improve Caltrans material specifications, test methods, and construction procedures used in the construction of transportation facilities that improve mobility across California, working with the Industry and the Federal Highway Administration.”
* Between 2-­8% of all concrete produced in California is returned to the batch plant.
* CalEPA’s Climate Action Team estimates that this corresponds to 2,200,000 lb of CO2 excess per year.
* At the request of the RPC Materials & QA STG, Climate Earth provided an in depth analysis on the potential carbon footprint reduction that would be realized if Caltrans were to pursue the use of recycled plastic concrete.

Precedence Considered:
Other transportation agencies have adopted the use of recycled aggregates for certain applications.
The Greenbook Standard Specifications were taken into consideration during the specification development.
California Public Resources Code and the US Environmental Protection Agency’s CISTIC protocol were also referenced for the development of the specifications.

Specifications:
Contractors are now allowed to use returned plastic concrete for certain applications provided that certain criteria are met.
Some of the criteria that must now be met include the following:
The weighmaster certificate must be submitted along with:
* Quantity of returned plastic concrete.
* Time, type, brand and dosage of the hydration stabilizing admixture (HSA).
* Copy of the original weighmaster certificate of the returned plastic concrete.
* Batch plant must have an endorsement complying with the Department’s MPQP.

Other Requirements:
Concrete may contain a maximum of 15 percent returned plastic concrete.
Returned plastic concrete must not exceed 100° F at any time.
Must be proportioned within 4 hours after original batching if HSA is not used.
If HSA is used, HSA must be added within 4 hours of original batching and returned plastic concrete must be proportioned within 4 hours after adding HSA.

Benefits:
Study found that 15% recycling returned plastic concrete would result in a 15.3% reduction in carbon footprint (in kgCO2e/cyd) and a 16.2% reduction in embodied energy for 1 CYD concrete mix.
Study located at:
* Reduced waste materials sent to landfills.
* Conservation of natural resources such as water, aggregate and cement.
* Decreased transportation impacts associated with shipping waste material and replacement material.
* Decreased overall project costs.

Applications:
Cement slurry
Curb, gutter and sidewalks.

Caltrans Projects:
2015 Caltrans projects: 07-3X7114, 05-1C0904, 03-0F4004, 05-1F5704, 03-1F4004

2016 Caltrans projects: 10-0T8104, 05-330784, 07-300604, 03-1F9904, 05-330784

As Reported by: Charley Rea of CalCIMA